;============================================================================= ; GSD-Datei nach DIN 19245 Teil 3 fuer COPRA Silica ;============================================================================= ; ; DATEINAME : CPS-FA01.GSD ;----------------------------------------------------------------------------- ; GERAET : COPRA Silica ;----------------------------------------------------------------------------- ; PROTOKOLL : Profibus DP (Slave) ;----------------------------------------------------------------------------- ; HERSTELLER : Swan Analytical Instruments ;----------------------------------------------------------------------------- ; VERTRIEB : Swan Analytical Instruments ; Postfach 3 ; CH-8616 Riedikon/Uster ; SCHWEIZ ; Tel : +41 (1) 943 63 00 ; Fax : +41 (1) 943 63 01 ; E-Mail : martin.stoffel@swan.ch ;----------------------------------------------------------------------------- ; VERSION : 4.1 ;----------------------------------------------------------------------------- ; DATUM : 17.09.2001 ;----------------------------------------------------------------------------- ; AENDERUNGEN: ; 17.09.2001 Min_Slave_Interval von 30 auf 80 erhoeht ; ; ; ;============================================================================= #Profibus_DP ; Anfangskennung GSD_Revision = 1 ; Versionskennung Vendor_Name = "SWAN AG" ; Herstellername Model_Name = "COPRA Silica" ; Produktebezeichnung Revision = "Rev. 4.1" ; Ausgabestand Ident_Number = 0xFA01 ; Identnummer Hex Protocol_Ident = 0 ; Protokollkennung : DP-Geraet Station_Type = 0 ; Geraetetyp : Slave FMS_supp = 0 ; kein FMS-Support ; Hardware_Release = "COMCOM V1.1" ; Hardware Ausgabestand Software_Release = "COMCOM V4.1" ; Software Ausgabestand ; 9.6_supp = 1 ; unterstuetzte Baudraten 19.2_supp = 1 93.75_supp = 1 187.5_supp = 1 500_supp = 1 1.5M_supp = 1 ; MaxTsdr_9.6 = 60 ; max. Antwortzeiten MaxTsdr_19.2 = 60 MaxTsdr_93.75 = 60 MaxTsdr_187.5 = 60 MaxTsdr_500 = 100 MaxTsdr_1.5M = 150 ; Redundancy = 0 ; Keine redundante Uebertragungstechnik Repeater_Ctrl_Sig = 0 ; CNTR-P nicht vorhanden 24V_Pins = 0 ; 24V nicht vorhanden Implementation_Type = "SLCDPC" ; SWAN Low Cost DP Controller Bitmap_Device = "CPS-DEV" ; Bitmap Dateien Bitmap_Diag = "CPS-DIA" Bitmap_SF = "CPS-SF" ; ;============================================================================= ; Slave spezifische Daten ;============================================================================= Freeze_Mode_supp = 1 ; Freeze wird unterstuetzt Sync_Mode_supp = 1 ; Sync wird unterstuetzt Auto_Baud_supp = 1 ; autom. Baudratensuche wird unterstuetzt Set_Slave_Add_supp = 1 ; der Dienst Set_Slave_Add wird unterstuetzt Min_Slave_Intervall = 80 ; Zeit zwischen zwei Slavelistenumlaeufen Fail_Safe = 1 ; Fail Safe Mode unterstuetzt Slave_Family=5@TdF@CONTROLLER Max_Diag_Data_Len = 14 ; Hoechstlaenge Diag_Data User_Prm_Data_Len = 8 ; Erweiterte Parametrierwerte User_Prm_Data = 0,0,0,0,0,0,0,0 ; Vorzubelegende Werte ;============================================================================= ; Modular beschriebene Kompakstation ; Es kann max. 1 Modul aus den zur Verfuegung stehenden Modulen ; ausgewaehlt werden ;============================================================================= Modular_Station = 1 ; Produktbeschreibung : Modular Max_Module = 1 ; max. 1 Modul Max_Input_Len = 32 ; max. Anzahl der Eingaenge Max_Output_Len = 6 ; max. Anzahl der Ausgaenge Max_Data_Len = 38 ; max. Summe der Ein- und Ausgangsdaten ;============================================================================= ; Geraetespezifische Diagnose ;============================================================================= Unit_Diag_Bit(0) = "Limit CH 0" Unit_Diag_Bit(1) = "Limit CH 1" Unit_Diag_Bit(2) = "Limit CH 2" Unit_Diag_Bit(3) = "Limit CH 3" Unit_Diag_Bit(4) = "Limit CH 4" Unit_Diag_Bit(5) = "Limit CH 5" Unit_Diag_Bit(6) = "Stablility" Unit_Diag_Bit(7) = "Reserved" Unit_Diag_Bit(8) = "Flow CH 0" Unit_Diag_Bit(9) = "Flow CH 1" Unit_Diag_Bit(10) = "Flow CH 2" Unit_Diag_Bit(11) = "Flow CH 3" Unit_Diag_Bit(12) = "Flow CH 4" Unit_Diag_Bit(13) = "Flow CH 5" Unit_Diag_Bit(14) = "Reagents 1" Unit_Diag_Bit(15) = "Reagents 2" Unit_Diag_Bit(16) = "Fotometer Zero" Unit_Diag_Bit(17) = "Fotometer Slope" Unit_Diag_Bit(18) = "Valve blocked" Unit_Diag_Bit(19) = "Cycle Timeout" Unit_Diag_Bit(20) = "Cal Zero" Unit_Diag_Bit(21) = "Cal Slope" Unit_Diag_Bit(22) = "Cal Blank" Unit_Diag_Bit(23) = "Temp too high" Unit_Diag_Bit(24) = "FM Connection" Unit_Diag_Bit(25) = "IIC Comm" Unit_Diag_Bit(26) = "ISP-0 Comm" Unit_Diag_Bit(27) = "ISP-1 Comm" Unit_Diag_Bit(28) = "Reserved" Unit_Diag_Bit(29) = "Flash" Unit_Diag_Bit(30) = "EEProm Mainboard" Unit_Diag_Bit(31) = "EEProm Frontend" ;============================================================================= ; Module, wort-organisiert, Konsistenz gesamte Laenge ;============================================================================= Module = " Keine Parameter / 1 Wort PD" 0x00,0xD0 EndModule Module = " Keine Parameter / 2 Wort PD" 0x00,0xD1 EndModule Module = " Keine Parameter / 3 Wort PD" 0x00,0xD2 EndModule Module = " Keine Parameter / 4 Wort PD" 0x00,0xD3 EndModule Module = " Keine Parameter / 5 Wort PD" 0x00,0xD4 EndModule Module = " Keine Parameter / 6 Wort PD" 0x00,0xD5 EndModule Module = " Keine Parameter / 7 Wort PD" 0x00,0xD6 EndModule Module = " Keine Parameter / 8 Wort PD" 0x00,0xD7 EndModule Module = " Keine Parameter / 9 Wort PD" 0x00,0xD8 EndModule Module = " Keine Parameter / 10 Wort PD" 0x00,0xD9 EndModule Module = " Keine Parameter / 11 Wort PD" 0x00,0xDA EndModule Module = " Keine Parameter / 12 Wort PD" 0x00,0xDB EndModule Module = " Keine Parameter / 13 Wort PD" 0x00,0xDC EndModule Module = " Keine Parameter / 14 Wort PD" 0x00,0xDD EndModule Module = " Keine Parameter / 15 Wort PD" 0x00,0xDE EndModule Module = " Keine Parameter / 16 Wort PD" 0x00,0xDF EndModule ; Module = "3 Wort Parameter / Keine PD" 0xF2,0x00 EndModule Module = "3 Wort Parameter / 1 Wort PD" 0xF2,0xD0 EndModule Module = "3 Wort Parameter / 2 Wort PD" 0xF2,0xD1 EndModule Module = "3 Wort Parameter / 3 Wort PD" 0xF2,0xD2 EndModule Module = "3 Wort Parameter / 4 Wort PD" 0xF2,0xD3 EndModule Module = "3 Wort Parameter / 5 Wort PD" 0xF2,0xD4 EndModule Module = "3 Wort Parameter / 6 Wort PD" 0xF2,0xD5 EndModule Module = "3 Wort Parameter / 7 Wort PD" 0xF2,0xD6 EndModule Module = "3 Wort Parameter / 8 Wort PD" 0xF2,0xD7 EndModule Module = "3 Wort Parameter / 9 Wort PD" 0xF2,0xD8 EndModule Module = "3 Wort Parameter / 10 Wort PD" 0xF2,0xD9 EndModule Module = "3 Wort Parameter / 11 Wort PD" 0xF2,0xDA EndModule Module = "3 Wort Parameter / 12 Wort PD" 0xF2,0xDB EndModule Module = "3 Wort Parameter / 13 Wort PD" 0xF2,0xDC EndModule ;============================================================================= ; Ende der GSD-Datei ;=============================================================================