;--------------------------------------------------------------------------- ; GSD file for PRetrans 6350 ; Company: PR electronics A/S ; Version: 1.00 ; Date: 12 Sept 2003 ;--------------------------------------------------------------------------- #Profibus_DP ; *** General *** GSD_Revision = 3 Vendor_Name = "PR electronics A/S" Model_Name = "PRetrans 6350" Revision = "1.0" Ident_Number = 0x6350 Protocol_Ident = 0 Station_Type = 0 FMS_supp = 0 Hardware_Release = "63509002" Software_Release = "V2.03 PA01" 9.6_supp = 0 19.2_supp = 0 31.25_supp = 1 45.45_supp = 1 93.75_supp = 1 187.5_supp = 0 500_supp = 0 1.5M_supp = 0 3M_supp = 0 6M_supp = 0 12M_supp = 0 MaxTsdr_9.6 = 60 MaxTsdr_19.2 = 60 MaxTsdr_31.25 = 100 MaxTsdr_45.45 = 250 MaxTsdr_93.75 = 1000 MaxTsdr_187.5 = 60 MaxTsdr_500 = 100 MaxTsdr_1.5M = 150 MaxTsdr_3M = 250 MaxTsdr_6M = 450 MaxTsdr_12M = 800 Redundancy = 0 Repeater_Ctrl_Sig = 0 24V_Pins = 0 ; *** Bitmaps *** Bitmap_Device = "PR6350N" Bitmap_Diag = "PR6350D" Bitmap_SF = "PR6350S" ; *** Slave Specification *** Freeze_Mode_supp = 0 Sync_Mode_supp = 0 Auto_Baud_supp = 0 Set_Slave_Add_Supp = 1 Min_Slave_Intervall = 250 Modular_Station = 1 Max_Module = 2 Max_Input_Len = 10 Max_Output_Len = 0 Max_Data_Len = 10 Fail_Safe = 0 Max_Diag_Data_Len = 14 Slave_Family = 12 ; *** UserPrmData: Length and Preset *** Max_User_Prm_Data_Len = 3 Ext_User_Prm_Data_Const(0) = 0x00,0x00,0x00 ; *** Description of extended DP features *** DPV1_Slave = 1 C2_Read_Write_supp = 1 C2_Max_Data_Len = 128 C2_Read_Write_required = 1 C2_Max_Count_Channels = 3 C2_Response_Timeout = 4000 DPV1_Data_Types = 1 Max_Initiate_PDU_Length = 52 ; *** Description of physical interface for async. and sync. transmission *** Physical_Interface = 0 Transmission_Delay_45.45 = 0 Reaction_Delay_45.45 = 0 Transmission_Delay_93.75 = 0 Reaction_Delay_93.75 = 0 End_Physical_Interface Physical_Interface = 1 Transmission_Delay_31.25 = 0 Reaction_Delay_31.25 = 0 End_Physical_Interface ; *** Description of device related diagnosis *** Unit_Diag_Bit(16) = "Error appears" Unit_Diag_Bit(17) = "Error disappears" Unit_Diag_Bit(24) = "Hardware failure electronics" Unit_Diag_Bit(25) = "Hardware failure mechanics" Unit_Diag_Bit(26) = "Motor temperature too high" Unit_Diag_Bit(27) = "Electronic temperature too high" Unit_Diag_Bit(28) = "Memory error" Unit_Diag_Bit(29) = "Measurement failure" Unit_Diag_Bit(30) = "Device not initialized" Unit_Diag_Bit(31) = "Device initialization failed" Unit_Diag_Bit(32) = "Zero point error" Unit_Diag_Bit(33) = "Power supply failed" Unit_Diag_Bit(34) = "Configuration invalid" Unit_Diag_Bit(35) = "Restart" Unit_Diag_Bit(36) = "Coldstart" Unit_Diag_Bit(37) = "Maintenance required" Unit_Diag_Bit(38) = "Characteristics invalid" Unit_Diag_Bit(39) = "Ident_Number violation" Unit_Diag_Bit(55) = "Extension Available" ; *** Module Definition List for Analog Input *** Module = "Empty Module" 0x00 1 EndModule Module = "Analog Input (AI) short" 0x94 2 EndModule Module = "Analog Input (AI) long" 0x42,0x84,0x08,0x05 3 EndModule ; *** Description of the module assignment *** SlotDefinition Slot(1) = "Analog Input Block 1" 2 1,2,3 Slot(2) = "Analog Input Block 2" 2 1,2,3 EndSlotDefinition