;=================================================================== ;GSD-Datei for Profibus DP-DT Modul from HMS Fieldbus Systems AB ; ;Stand : 27.01.1997 ;File : HMS_1002.GSD ;=================================================================== #Profibus_DP ; Unit-Defination-List: GSD_Revision = 1 Vendor_Name = "HMS Fieldbus Systems AB" Model_Name = "AB-DT-PDP" Revision = "Version 1.4" Ident_Number = 0x1002 Protocol_Ident = 0 Station_Type = 0 ; DP-Slave FMS_supp = 0 ; no FMS/DP Mixed Device Hardware_Release = "Version 1.0" Software_Release = "Version 1.0" ; 9.6_supp = 1 ;baud rate supported 19.2_supp = 1 ;baud rate supported 93.75_supp = 1 ;baud rate supported 187.5_supp = 1 ;baud rate supported 500_supp = 1 ;baud rate supported 1.5M_supp = 1 ;baud rate supported 3M_supp = 1 ;baud rate supported 6M_supp = 1 ;baud rate supported 12M_supp = 1 ;baud rate supported ; Duration to answer a request by a responder MaxTsdr_9.6 = 60 MaxTsdr_19.2 = 60 MaxTsdr_93.75 = 60 MaxTsdr_187.5 = 60 MaxTsdr_500 = 100 MaxTsdr_1.5M = 150 MaxTsdr_3M = 250 MaxTsdr_6M = 450 MaxTsdr_12M = 800 ; Redundancy = 0 ; redund. Transceiver not supp. Repeater_Ctrl_Sig = 2 ; TTL 24V_Pins = 0 ; Not connected ; Implementation_Type = "SPC3" Bitmap_Device = "DP_NORM" ; ; Slave-Specification: Freeze_Mode_supp = 1 ; Freeze-Mode supported Sync_Mode_supp = 1 ; Sync-Mode supported Auto_Baud_supp = 1 ; auto. Baud. detec. supp. Set_Slave_Add_supp = 0 ; Set_Slave_Add not supported Min_Slave_Intervall = 10 ; Modular_Station = 1 Max_Module = 24 Max_Input_Len = 200 Max_Output_Len = 200 Max_Data_Len = 400 Modul_Offset = 200 ; Fail_Safe = 0 ; data telegram without data in ; ; state CLEAR not accepted Slave_Family = 0 Max_Diag_Data_Len = 16 ; Unit_Diag_Bit(0) = "OK" Unit_Diag_Bit(1) = "ERROR 1" Unit_Diag_Bit(2) = "ERROR 2" Unit_Diag_Bit(3) = "ERROR 3" Unit_Diag_Bit(4) = "ERROR 4" Unit_Diag_Bit(127) = "ERROR 127" ; Module = "INPUT/OUTPUT: 1 Byte" 0x30 EndModule Module = "INPUT/OUTPUT: 2 Byte " 0x70 EndModule Module = "INPUT/OUTPUT: 4 Byte " 0x71 EndModule Module = "INPUT/OUTPUT: 8 Byte" 0x73 EndModule Module = "INPUT/OUTPUT: 16 Byte" 0x77 EndModule Module = "INPUT/OUTPUT: 32 Byte" 0x7F EndModule Module = "INPUT/OUTPUT: 64 Byte" 0xC0,0x5F,0x5F EndModule Module = "INPUT/OUTPUT: 128 Byte" 0xC0,0x7F,0x7F EndModule Module = "INPUT: 1 Byte" 0x10 EndModule Module = "INPUT: 2 Byte" 0x50 EndModule Module = "INPUT: 4 Byte" 0x51 EndModule Module = "INPUT: 8 Byte" 0x53 EndModule Module = "INPUT: 16 Byte" 0x57 EndModule Module = "INPUT: 32 Byte" 0x5F EndModule Module = "INPUT: 64 Byte" 0x40,0x5F EndModule Module = "INPUT: 128 Byte" 0x40,0x7F EndModule Module = "OUTPUT: 1 Byte" 0x20 EndModule Module = "OUTPUT: 2 Byte" 0x60 EndModule Module = "OUTPUT: 4 Byte" 0x61 EndModule Module = "OUTPUT: 8 Byte" 0x63 EndModule Module = "OUTPUT: 16 Byte" 0x67 EndModule Module = "OUTPUT: 32 Byte" 0x6F EndModule Module = "OUTPUT: 64 Byte" 0x80,0x5F EndModule Module = "OUTPUT 128 Byte" 0x80,0x7F EndModule