;************************ COMPANY INFORMATION ************************* ;* * ;* CREATED by Endress+Hauser GmbH+Co * ;* PUBLISHED by Endress+Hauser Process Solutions AG, CH-4153 Reinach * ;* * ;******************** DEVICE and FILE INFORMATION ********************* ;* * ;* FILE NAME: Eh__151d.gsd * ;* DEVICE TYPE: PROFIBUS-DP * ;* DEVICE INFORMATION: Liquisys S CCM2x3 DP * ;* PROFILE COMPATIBILITY: PROFILE 2.0 * ;* DPV1 IMPLEMENTATION: yes * ;* * ;********************** GSD REVISION INFORMATION ********************** ;* $Revision:: 1.0 $ * ;* $Date:: 05 Apr 2000 $ * ;* * ;* DATE | NAME | VERSION | COMMENT * ;* ---------------------------------------------------------------------- * ;* 05.04.2000 | Gl | 1.0 | first release * ;* | | | * ;************************************************************************** #Profibus_DP ;**************************** General DP Keywords *********************** GSD_Revision = 2 Vendor_Name = "Endress + Hauser" Model_Name = "Liquisys S CCM2x3 DP" Revision = "Profile 2.0" Ident_Number = 0x151d Protocol_Ident = 0 Station_Type = 0 FMS_supp = 0 Hardware_Release = "all" Software_Release = "2.10" 9.6_supp = 1 19.2_supp = 1 31.25_supp = 0 45.45_supp = 0 93.75_supp = 1 187.5_supp = 1 500_supp = 1 1.5M_supp = 1 3M_supp = 1 6M_supp = 1 12M_supp = 1 MaxTsdr_9.6 = 60 MaxTsdr_19.2 = 60 MaxTsdr_93.75 = 60 MaxTsdr_187.5 = 60 MaxTsdr_500 = 100 MaxTsdr_1.5M = 150 MaxTsdr_3M = 250 MaxTsdr_6M = 450 MaxTsdr_12M = 800 Implementation_Type = "SPC4/ITEC" Bitmap_Device = "Eh151d_n" Bitmap_Diag = "Eh151d_d" Bitmap_SF = "Eh151d_s" ;********* Additional Keywords For Different Phsical Interfaces ********* ;***************** DP Master (Class 1) Related Keywords ***************** ;********* Additional Master Related Keywords For DP Extensions ********* ;******************** Basic DP-Slave Related Keywords ******************* Freeze_Mode_supp = 1 Sync_Mode_supp = 0 Auto_Baud_supp = 1 Set_Slave_Add_supp = 1 User_Prm_Data_Len = 3 User_Prm_Data = 0, 0, 0 Min_Slave_Intervall = 6 Modular_Station = 1 Max_Module = 3 Max_Input_Len = 15 Max_Output_Len = 0 Max_Data_Len = 15 Max_Diag_Data_Len = 6 Module = "Main measurement value" 0x94 EndModule Module = "Temperature value" 0x94 EndModule Module = "pH/Redox measurement value" 0x94 EndModule Module = "Free Place" 0x00 EndModule Slave_Family = 0 ;************** Additional Keywords For Modul Assignment **************** ;*************** Slave Related Keywords For DP Extensions *************** ;************* Slave Related Keywords For ProfiSafe Profile *************