;************************ COMPANY INFORMATION ************************* ;* * ;* CREATED by Endress+Hauser Conducta GmbH+Co. KG * ;* PUBLISHED by Endress+Hauser Process Solutions AG, CH-4153 Reinach * ;* * ;******************** DEVICE and FILE INFORMATION ********************* ;* * ;* FILE NAME: EH3X1535.GSD * ;* DEVICE TYPE: PROFIBUS-PA * ;* DEVICE INFORMATION: MYCOM S CLM153cd * ;* PROFILE COMPATIBILITY: PROFILE 3.0 * ;* DPV1 IMPLEMENTATION: MSAC2_Read/Write * ;* IDENTIFIER FORMAT: Extended * ;* * ;********************** GSD REVISION INFORMATION ********************** ;* Revision: 1.0 * ;* Date: 10.06.02 * ;* * ;* DATE | NAME | VERSION | COMMENT * ;* ---------------------------------------------------------------------- * ;* 04.06.2002 | Gl | 1.0 | initial revision * ;* 24.09.2002 | Gl | 1.1 | Profil 3.0 conform manufact. spec. data * ;************************************************************************** ;************************* General DP Key Words ************************* #Profibus_DP GSD_Revision = 4 Vendor_Name = "Endress + Hauser" Model_Name = "MYCOM CLM153cd PA" Revision = "Profile 3.0" Ident_Number = 0x1535 Protocol_Ident = 0 Station_Type = 0 FMS_supp = 0 Hardware_Release = "All 1" Software_Release = "All 2" 31.25_supp = 1 45.45_supp = 1 93.75_supp = 1 MaxTsdr_31.25 = 100 MaxTsdr_45.45 = 250 MaxTsdr_93.75 = 1000 Implementation_Type = "SPC4/ITEC" Bitmap_Device = "EH1535_N" Bitmap_Diag = "EH1535_D" Bitmap_SF = "EH1535_S" ;********* Additional keywords for different physical interfaces ******** ;***************** DP Master (Class 1) Related Key Words **************** ;********* Additional master related keywords for DP extensions ********* ;************** Additional master related keywords for DPV2 ************* ;******************* Basic DP-Slave Related Key Words ******************* Freeze_Mode_supp = 1 Sync_Mode_supp = 1 Auto_Baud_supp = 0 Set_Slave_Add_supp = 1 Min_Slave_Intervall = 250 Modular_Station = 1 Max_Module = 5 Max_Input_Len = 20 Max_Output_Len = 2 Max_Data_Len = 22 Max_Diag_Data_Len = 20 Slave_Family = 12 User_Prm_Data_Len = 3 User_Prm_Data = 0, 0, 0 Unit_Diag_Bit(16) = "Error appears" Unit_Diag_Bit(17) = "Error disappears" Unit_Diag_Bit(24) = "Hardware failure electronics" Unit_Diag_Bit(25) = "Hardware failure mechanics" Unit_Diag_Bit(26) = "Motor temperature too high" Unit_Diag_Bit(27) = "Electronic temperature too high" Unit_Diag_Bit(28) = "Memory error" Unit_Diag_Bit(29) = "Measurement failure" Unit_Diag_Bit(30) = "Device not initialized" Unit_Diag_Bit(31) = "Device initialization failed" Unit_Diag_Bit(32) = "Zero point error" Unit_Diag_Bit(33) = "Power supply failed" Unit_Diag_Bit(34) = "Configuration invalid" Unit_Diag_Bit(35) = "Restart" Unit_Diag_Bit(36) = "Coldstart" Unit_Diag_Bit(37) = "Maintenance required" Unit_Diag_Bit(38) = "Characteristics invalid" Unit_Diag_Bit(39) = "Ident_Number violation" Unit_Diag_Bit(55) = "Extension Available" Unit_Diag_Bit(56) = "A: Memory error" Unit_Diag_Bit(57) = "A: Data error in EEPROM" Unit_Diag_Bit(58) = "A: Invalid configuration" Unit_Diag_Bit(59) = "A: Incompatible hardware" Unit_Diag_Bit(60) = "A: Error transmitter" Unit_Diag_Bit(61) = "A: Error sensor" Unit_Diag_Bit(65) = "A: Delta limit exceeded" Unit_Diag_Bit(68) = "A: Limit Airset Offset exceeded" Unit_Diag_Bit(69) = "A: Calibration out of range" Unit_Diag_Bit(70) = "A: Adapt.factor out of range" Unit_Diag_Bit(71) = "A: Actuator failure" Unit_Diag_Bit(72) = "A: Main PV out of range" Unit_Diag_Bit(73) = "A: Temperature out of range" Unit_Diag_Bit(74) = "A: Temp. out of alphatable" Unit_Diag_Bit(75) = "A: Download error" Unit_Diag_Bit(76) = "A: Polarisation error" Unit_Diag_Bit(77) = "A: Measvalue out of conc.table" Unit_Diag_Bit(80) = "W: Delta limit exceeded" Unit_Diag_Bit(85) = "W: Dos.time alert" Unit_Diag_Bit(86) = "W: Set point exceeded GWG" Unit_Diag_Bit(87) = "W: PCS alarm" Unit_Diag_Bit(88) = "W: USP error" Unit_Diag_Bit(89) = "W: Current input 1 out of range" Unit_Diag_Bit(90) = "W: Current input 2 out of range" Unit_Diag_Bit(103) = "F: Simulation active" Module = "Main Process Value" 0x42,0x84,0x08,0x05 1 EndModule Module = "Main Temperature" 0x42,0x84,0x08,0x05 2 EndModule Module = "2nd Process Value" 0x42,0x84,0x08,0x05 3 EndModule Module = "2nd Temperature" 0x42,0x84,0x08,0x05 4 EndModule Module = "Control CLM" 0x82,0x81,0x05,0x05 5 EndModule Module = "Free Place" 0x00 6 EndModule ;*************** Additional keywords for module assignment ************** SlotDefinition Slot(1) = "Main Process Value" 1 1,6 Slot(2) = "Main Temperature" 2 2,6 Slot(3) = "2nd Process Value" 3 3,6 Slot(4) = "2nd Temperature" 4 4,6 Slot(5) = "Control CLM" 5 5,6 EndSlotDefinition ;*************** Slave related keywords for DP extensions *************** DPV1_Slave = 1 C2_Read_Write_supp = 1 C2_Max_Data_Len = 48 C2_Response_Timeout = 250 C2_Max_Count_Channels = 2 Max_Initiate_PDU_Length = 52 ;******** Slave related keywords for Data Exchange with Broadcast ******* ;*************** Slave related keywords for Isochron Mode *************** ;************* Slave related keywords for ProfiSafe Profile ************* ;********* Slave related keywords for extended parametrization ********** ;***************** Slave related keywords for Subsystems ****************