;========================================================================================== ; GSE file for ABB Automation PA-Slave ; Device : TRIOWIRL V_4000/S_4000 ; Date : 28.08.2002 ;========================================================================================== #Profibus_DP GSD_Revision = 3 Vendor_Name = "ABB Automation" Model_Name = "TRIOWIRL V_4000/S_4000" Revision = "Profil 3.0" Ident_Number = 0x05DC Protocol_Ident = 0 Station_Type = 0 FMS_supp = 0 Hardware_Release = "Revision 0" Software_Release = "D200F003U01 A.15" Bitmap_Device = "ABB05DCn" Bitmap_Diag = "ABB05DCd" Bitmap_SF = "ABB05DCs" 31.25_supp = 1 45.45_supp = 1 93.75_supp = 1 MaxTsdr_31.25 = 100 MaxTsdr_45.45 = 250 MaxTsdr_93.75 = 1000 Redundancy = 0 Repeater_Ctrl_Sig = 0 24V_Pins = 0 Freeze_Mode_supp = 0 Sync_Mode_supp = 0 Set_Slave_Add_supp = 1 Min_Slave_Intervall = 100 Modular_Station = 1 Max_Module = 3 Max_Input_Len = 15 Max_Output_Len = 2 Max_Data_Len = 17 Slave_Family = 12 Max_Diag_Data_Len = 20 Max_User_Prm_Data_Len = 3 Ext_User_Prm_Data_Const(0) = 0x00, 0x00, 0x00 ;------------------------------------------------------------------------- ; Description of extended DP features ;------------------------------------------------------------------------- DPV1_Slave = 1 C2_Read_Write_supp = 1 C2_Max_Data_Len = 220 C2_Read_Write_required = 1 C2_Max_Count_Channels = 3 Max_Initiate_PDU_Length = 52 C2_Response_Timeout = 4000 DPV1_Data_Types = 0 ;------------------------------------------------------------------------- ; Description of physical interface for async. and sync. transmission ;------------------------------------------------------------------------- Physical_Interface = 0 Transmission_Delay_45.45 = 0 Reaction_Delay_45.45 = 0 Transmission_Delay_93.75 = 0 Reaction_Delay_93.75 = 0 End_Physical_Interface Physical_Interface = 1 Transmission_Delay_31.25 = 0 Reaction_Delay_31.25 = 0 End_Physical_Interface ;------------------------------------------------------------------------- ; Description of device related diagnosis ;------------------------------------------------------------------------- Unit_Diag_Bit(16) = "Error appears" Unit_Diag_Bit(17) = "Error disappears" Unit_Diag_Bit(24) = "Hardware failure electronics" Unit_Diag_Bit(28) = "Memory error" Unit_Diag_Bit(29) = "Measurement failure" Unit_Diag_Bit(55) = "Extension Available" Unit_Diag_Bit(57) = "Qv> 115% QmaxDN" Unit_Diag_Bit(59) = "Backup DataBase" Unit_Diag_Bit(64) = "Steam Calculation" Unit_Diag_Bit(65) = "FrontEnd" Unit_Diag_Bit(67) = "Q > 115% Qmax" Unit_Diag_Bit(69) = "Main DataBase" Unit_Diag_Bit(70) = "TB-Totalizer" Unit_Diag_Bit(71) = "Temperature" Unit_Diag_Bit(72) = "Max.Temperature Alarm" Unit_Diag_Bit(73) = "Min.Temperature Alarm" Unit_Diag_Bit(75) = "Max.Flow Alarm" Unit_Diag_Bit(76) = "Min.Flow Alarm" Unit_Diag_Bit(84) = "Selfcheck Pulse Output" Unit_Diag_Bit(85) = "Selfcheck Switch.Output" Unit_Diag_Bit(86) = "Selfcheck Flow simulation" ;------------------------------------------------------------------------- ;Empty module Module = "EMPTY_MODULE" 0x00 1 EndModule ; ;Modules for flow meter Module = "AI" 0x94 2 EndModule ; Module = "TOTAL" 0x41,0x84,0x85 3 EndModule ; Module = "SETTOT_TOTAL" 0xC1,0x80,0x84,0x85 4 EndModule ; Module = "SETTOT_MODETOT_TOTAL" 0xC1,0x81,0x84,0x85 5 EndModule ;----------- Description of the module assignment: --------------------- ; SlotDefinition Slot(1) = "AI1" 2 1,2 Slot(2) = "Totalizer" 3 1,3,4,5 Slot(3) = "AI2" 2 1,2 EndSlotDefinition